endress+hauser Cerabar PMP23
Benefits
Easy and time-saving installation and set up within the plant due to very compact construction and customizable measuring ranges
IO-link reduces costs and complexity due to easy configuration via simple configuration tools or through the engineering system
Fully welded process connections maximize process safety by minimizing the use of gaskets
Enhanced process availability is ensured by the stringent use of 316L material and the possibility of IP 69 ingress protection for washdown conditions, as well as the high reproducibility and long-term stability of the product
A high flexibility of use and therefore lower storage costs are guaranteed as the PMP23 is suitable for CIP / SIP cleaning
The PMP23 can support the need for hygienic documentation and traceability in the plant as certification such as EHEDG, 3-A or (EC)1935/2004 are available among other relevant certificates and manufacturing declarations
Field of application
Pressure transducer to measure absolute or gauge pressure in gases or liquids.
Process connections: Flush-mounted hygienic connections, flush mounted thread connections
Process temperature: -10°C to +100°C (-40°F to +212°F) and +135°C (+275°F) for max. 1h
Process pressure: 400mbar to +40bar (6 to 600psi)
Accuracy: ±0.3% of span
International explosion protection certificates, hygienic certificates
Features and specifications
Measuring principle
Absolute and gauge pressure
Characteristic
Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
Supply voltage
10…30 VDC
Reference Accuracy
0.3 %
Long term stability
0.2 % of URL/year